YP Series Variable Frequency AC Motor

    Cooling a Motor at 5 Hz Without Derating Keywords: Separately Ventilated VFD Motor / Constant Torque at Low Speed / Forced Cooling Inverter Motor The problem with a shaft-mounted fan A conventional TEFC motor carries a fan on the shaft. At rated speed the fan moves enough air to hold the winding at its design temperature. At 25% speed the fan moves roughly 25% of the air, but the motor may still be asked for full torque — and full torque means full current, which means full heat, with a quarter of the cooling. That is the single most common cause of variable-speed motor failure: not the drive, not the winding insulation, but thermal derating that nobody applied. The solution: cooling decoupled from speed YP uses forced ventilation with an independent fan — the cooling fan runs at its own speed, driven by its own small motor, regardless of what the main shaft is doing. 表格 Cooling arrangement Airflow at 25% speed Full torque available? Shaft-mounted fan (IC411) ≈ 25% No —…